+1 vote
in Irrigation Engineering by (75.2k points)
The downstream apron of the ogee spillway is found to have a negligible effect on the coefficient of discharge when the value of ________________

(a) (Hd + d) / He is less than 1.7

(b) (Hd + d) / He exceeds 1.7

(c) (Hd + d) / He is equal to 1

(d) (Hd + d) / He is less than 1.33

This question was addressed to me during an interview.

The question is from Ogee Profile in portion Spillways, Energy Dissipators and Spillway Gates of Irrigation Engineering

1 Answer

0 votes
by (106k points)
Correct option is (b) (Hd + d) / He exceeds 1.7

Explanation: The d/s apron is found to have a negligible effect on the coefficient of discharge when the value of (Hd + d) / He exceeds 1.7. where d is the tailwater depth, Hd is the design head and He is the Design head including the velocity head. There can be a decrease in the coefficient due to tailwater submergence.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...