+1 vote
in Irrigation Engineering by (75.2k points)
The greater is the divergence from the streamline flow, greater is the contraction coefficient.

(a) True

(b) False

This question was posed to me in an online interview.

My question comes from Ogee Profile in division Spillways, Energy Dissipators and Spillway Gates of Irrigation Engineering

1 Answer

0 votes
by (106k points)
Right answer is (a) True

To explain I would say: The greater is the divergence, the greater is the contraction coefficient and lesser is the effective length of the crest. A 90° cut water nose pier is generally preferred as it has quite a low value of pier contraction coefficient and is most efficient.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...