+1 vote
in Fluidization Engineering by (102k points)
Which type of distributor reduces channelling and slugging to maximum extent?

(a) Single orifice plate

(b) Multiple orifice plate

(c) Nozzle plate

(d) Sintered plate

This question was addressed to me in an interview for internship.

This intriguing question comes from Importance of the Distributor topic in portion Fluidization and Mapping of Regimes of Fluidization Engineering

1 Answer

+2 votes
by (103k points)
selected by
 
Best answer
Correct option is (d) Sintered plate

The best explanation: More the number of holes better is the distribution of air or fluid in the bed, hence less channelling and slugging.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...