+1 vote
in Irrigation Engineering by (75.2k points)
Standard USBR stilling basin-II is useful for energy dissipation at the bottom of the overflow structure, if the approaching Froude number is ________________

(a) less than 4.5

(b) more than 4.5

(c) less than 2.5

(d) more than 2.5

I got this question during an interview for a job.

I need to ask this question from Energy Dissipation Below Overflow Spillway in portion Spillways, Energy Dissipators and Spillway Gates of Irrigation Engineering

1 Answer

0 votes
by (106k points)
The correct answer is (b) more than 4.5

The explanation: USBR has standardized stilling basins for different Froude numbers. USBR stilling basin- II is recommended for large structures when the Froude number is more than 4.5. The dissipation of energy will be 45 to 85%.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...