+1 vote
in Irrigation Engineering by (75.2k points)
The discharge range of Gibb’s module varies from ____________

(a) 0.03 to 0.45 cumec

(b) 0.01 to 0.03 cumec

(c) 0.45 to 0.55 cumec

(d) 0.55 to 0.75 cumec

I have been asked this question in quiz.

My question comes from Types of Rigid Modules and Cattle Crossings topic in division Regulation Modules and Canal Structure of Irrigation Engineering

1 Answer

0 votes
by (106k points)
The correct option is (a) 0.03 to 0.45 cumec

To explain I would say: The discharge range of Gibb’s rigid module varies from 1 to 16 cusecs or 0.03 to 0.45 cumecs. It is often economical to construct it in R.C.C for lower values of discharge i.e. 1 to 3 cusecs. For discharge value greater than 3 cusecs it can be constructed in brick masonry.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...