+1 vote
in Irrigation Engineering by (75.2k points)
Calculate the minimum modular head loss involved in ASOM if the head measured from the upstream water level in the distributary is 1.5 m and the width of the throat as 0.16 m.

(a) 1.50 m

(b) 1.15 m

(c) 1.07 m

(d) 1.00 m

I have been asked this question at a job interview.

Question is from Regulation Modules topic in portion Regulation Modules and Canal Structure of Irrigation Engineering

1 Answer

0 votes
by (106k points)
Right answer is (b) 1.15 m

The explanation is: The minimum modular head loss involved in ASOM is given by the formula –

HL = 0.82 HS – W/2 where HS = Head measured from the U/s level in the distributary to the lowest point of the roof block and W = width of the throat

HL = (0.82 x 1.5) – 0.08 = 1.15 m.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...