+1 vote
in Geotechnical Engineering II by (93.7k points)
The limiting head of water value in pneumatic caisson is ________

(a) 40 m

(b) 25 m

(c) 35 m

(d) 50 m

This question was addressed to me at a job interview.

The question is from Well Foundations topic in section Well Foundations of Geotechnical Engineering II

1 Answer

0 votes
by (243k points)
Correct choice is (c) 35 m

Easiest explanation: As the maximum air pressure is limited to 3.5 kg /cm2. the limiting head of water is given by:

hlim = 3.5/0.1 = 35 m.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...