+2 votes
in Environmental Engineering by (81.4k points)
The runoff  in cumec by the Rational method is defined by ______________

(a) Q = K*A*I*R

(b) Q = (K+A+I) *R

(c) Q = (K+A) *R

(d) Q = A*I*R

The question was posed to me in a job interview.

My question is based upon Rational Method in portion Water Supply for Building, Collection and Conveyance of Sewage, Waste Water Flow Rate of Environmental Engineering

1 Answer

+2 votes
by (693k points)
selected by
 
Best answer
The correct choice is (a) Q = K*A*I*R

The best explanation: According to the Rational method, the storm water or runoff is defined by Q = K*A*I*R where, ‘K’ is a constant, ‘A’ is the catchment area in hectares,’I’ is the impermeability factor and ‘R’ is the intensity of rainfall in mm per hour.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...