+1 vote
in Irrigation Engineering by (75.2k points)
The width of the horizontal floors of type A and D weirs from the foot of the drop wall to the d/s edge of the floor should never be less than ________________

(a) 5 (D + H)

(b) 3 (D + H)

(c) 2.5 (D + H)

(d) 2 (D + H)

This question was posed to me in semester exam.

Origin of the question is Tank or Surplus Escape Weirs Design topic in division River Navigation & Tank Irrigation of Irrigation Engineering

1 Answer

0 votes
by (106k points)
The correct choice is (d) 2 (D + H)

The best I can explain: The width of the horizontal floor of Type-A and Type-D weirs should not be less than 2(D + H) and in important works, the width can be increased to 3(D + H). where D is the height of drop wall and H is the maximum head of water over the wall. The rough stone apron forming a talus below the last curtain wall generally vary from 2.5(D+ H) to 5(D + H) depending upon the nature of the soil and the velocity and annual probable quantity and intensity of run-off.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...