+1 vote
in Irrigation Engineering by (75.2k points)
According to Bligh, a vertical cut-off at U/s end of the floor is less useful than the one at the D/s end of the floor.

(a) True

(b) False

The question was asked in my homework.

I'm obligated to ask this question of Seepage Theories topic in section Seepage Theories and Weirs and Barrages Design of Irrigation Engineering

1 Answer

0 votes
by (106k points)
Right answer is (b) False

Explanation: The worst condition is that when the water level on U/s side is maximum and no water on D/s side. It would be more economical to provide more creep length on U/s side instead of D/s side. A vertical cut-off at U/s end is more useful than at the D/s end of the floor.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...