+1 vote
in Irrigation Engineering by (75.2k points)
How many corrections are needed for the complex profile broken from simple forms, to be valid?

(a) 1

(b) 2

(c) 3

(d) 4

The question was posed to me in final exam.

My question comes from Seepage Theories in chapter Seepage Theories and Weirs and Barrages Design of Irrigation Engineering

1 Answer

0 votes
by (106k points)
Correct answer is (c) 3

The explanation is: The corrections needed are correction for mutual interference of piles, correction for thickness of floor, and correction for slope of the floor.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...