+1 vote
in Irrigation Engineering by (75.2k points)
Suppose the culturable commanded for a distributary is 8000 hectares, and the intensity of irrigation for Kharif season is 60% and that of rabi season is 30%. The average duty at the head of a distributary is 4000 hectares/cumec for Kharif season and for Rabi season it is 1800 hectares/cumec, find out discharge required at the head of the distributary?

(a) 1.35 cumec

(b) 1.32 cumec

(c) 1.33 cumec

(d) 1.3 cumec

I got this question in semester exam.

My question is based upon Design Capacity for an Irrigation Canal in section Sediment Transport and Irrigation Channels Design of Irrigation Engineering

1 Answer

0 votes
by (106k points)
Right choice is (c) 1.33 cumec

To explain: Area to be irrigated in Kharif season = 8000 x 60/100 = 4800 hectares

Area to be irrigated in Rabi season = 8000 x 30/100 = 2400 hectares

Water required at the head of distributary to irrigate Kharif area = 4800 / 4000 = 1.2 cumec

Water required at the head of distributary to irrigate Rabi area = 2400 / 1800 = 1.33 cumec

Therefore, the required discharge is maximum of the two = 1.33 cumec.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...