Correct choice is (b) False
The best I can explain: The safety against sliding should be checked only for friction in case of low dams and in high dams, the shear strength of the joint (i.e. an additional shear resistance) is also considered for economical design. The dam section is given an extra slope or batter on the U/s or D/s side as per requirements for achieving stability.