+1 vote
in Geotechnical Engineering II by (93.8k points)
The cone resistance is approximately equal to ______ times the penetration resistance N.

(a) 10

(b) 20

(c) 30

(d) 40

I got this question during a job interview.

This intriguing question originated from Geophysical Methods in chapter Stabilisation of Soils, Site Investigation and Sub – Soil Exploration of Geotechnical Engineering II

1 Answer

0 votes
by (243k points)
Right answer is (a) 10

To explain: The cone resistance in kg/cm^2 is approximately equal to 10 times the penetration resistance N from the standard penetration test. The Dutch cone test is very useful in cohesion-less soils.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...