On calculating the natural frequency of the system, Barken did not take into account of __________

(a) Contact area

(b) Frequency ratio

(c) Mass of the vibrating soil

(d) Mass of machine

This question was posed to me in exam.

This is a very interesting question from Machine Foundations in chapter Machine Foundations of Geotechnical Engineering II

1 Answer

0 votes
by (243k points)
Correct choice is (c) Mass of the vibrating soil

The explanation: The formula suggested by Barken for natural frequency does not take into account of the mass of soil vibrating with the foundations.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...