The correct choice is (c) \(q=\frac{2πkb(H-h)}{log_e\frac{R}{r}}\)
The explanation is: The formula for discharge for drawdown of well is given by,
\(q=\frac{2πkb(H-h)}{log_e\frac{R}{r}}\)
where, \(\)q=discharge
k=coefficient of permeability
b=aquifer thickness
R=radius of influence
r=radius of tube well
(H-h)=drawdown.