+1 vote
in Fermentation Technology by (72.1k points)
Which of the following time is not included in continuous sterilization?

(a) Heating time

(b) Cooling time

(c) Holding time

(d) Sterilization time

I have been asked this question in my homework.

This intriguing question originated from Continuous Sterilization in division Sterilization of Fermentation Technology

1 Answer

+2 votes
by (424k points)
selected by
 
Best answer
Correct choice is (d) Sterilization time

The explanation is: The continuous sterilization includes the time period of heating where the medium is heated, followed by holding time where the medium is held at a certain temperature and finally the cooling period to restore the medium to the fermentation temperature.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...