+2 votes
in Environmental Engineering by (81.4k points)
The water supply pipes are buried underground. The load on the buried pipe due to earth filling is given by ____________

(a) W = C*Y*B

(b) W = C*Y/B

(c) W = C*Y*B^2

(d) W = C*Y2*B

This question was posed to me in an online interview.

This interesting question is from Layout of Distribution System in chapter Conveyance and Distribution of Water of Environmental Engineering

1 Answer

+2 votes
by (693k points)
selected by
 
Best answer
Correct option is (c) W = C*Y*B^2

Explanation: According to Marston, the load W on buried pipes due to earth filling is given by  W = C*Y*B^2 where, ‘C’ is the coefficient which depends on soil, ‘Y’ is the unit weight of back fill material and ‘B’ is the width of the trench.

Related questions

We welcome you to Carrieradda QnA with open heart. Our small community of enthusiastic learners are very helpful and supportive. Here on this platform you can ask questions and receive answers from other members of the community. We also monitor posted questions and answers periodically to maintain the quality and integrity of the platform. Hope you will join our beautiful community
...